Error Code

Message Information

Details

The memory may not be operational. This an early indicator
of a possible future uncorrectable error.

Action

Re-seat the memory modules. If the issue persists, see

Getting Help

.

MEM1205

Message

Memory mirror redundancy is lost. Check memory device at
location(s) <location>.

Details

The memory may not be seated correctly, misconfigured, or
has failed.

Action

Check the memory configuration. Re-seat the memory
modules. If the issue persists, see

Getting Help

.

MEM1208

Message

Memory spare redundancy is lost. Check memory device at
location <location>.

Details

Memory sparing is no longer available.

Action

Re-seat the memory modules. If the issue persists, see

Getting Help

.

MEM8000

Message

Correctable memory error logging disabled for a memory
device at location <location>.

Details

Errors are being corrected but no longer logged.

Action

Review system logs for memory exceptions. Reinstall
memory at location <location>.

PCI1302

Message

A bus time-out was detected on a component at bus <bus>
device<device> function <func>.

Details

System performance may be degraded. The device has failed
to respond to a transaction.

Action

Cycle input power, update component drivers, if device is
removable, reinstall the device.

PCI1304

Message

An I/O channel check error was detected.

Action

Cycle input power, update component drivers, if device is
removable, reinstall the device.

PCI1308

Message

A PCI parity error was detected on a component at bus
<bus>device<device>function <func>.

113