Dell PowerVault DR6000 User Manual

Page 115

Advertising
background image

Error Code

Message Information

PDR1016

Message

Drive <number> is removed from disk drive bay <bay>.

Details

The controller detected that the drive was removed.

Action

Verify drive installation. Re-seat the failed drive. If the issue
persists, see

Getting Help

.

PST0128

Message

No memory is detected.

Details

System BIOS was unable to detect memory in the system.

Action

Re-seat the memory modules. If the issue persists, see

Getting Help

.

PST0129

Message

Memory is detected, but is not configurable.

Details

System BIOS detected memory, but was unable to configure
the memory for system operation.

Action

Compare system memory installation to supported system
memory configurations.

PSU0001

Message

Power supply <number> failed.

Action

Remove and reinstall the power supply. If the issue persists,
see

Getting Help

.

PSU0002

Message

A predictive failure detected on power supply <number>.

Details

System performance and power redundancy may be
degraded or lost.

Action

Remove and reinstall the power supply at the next service
window. If the issue persists, see

Getting Help

.

PSU0003

Message

The power input for power supply <number> is lost.

Details

The power supply is installed correctly but an input source is
not connected or is not functional.

Action

Verify the input source is attached to the power supply.
Verify the input power is within the operating requirements
for the power supply.

PSU0006

Message

Power supply <number> type mismatch.

Details

Power supplies should be of the same input type and power
rating.

115

Advertising