Dell PowerEdge R410 User Manual

Page 26

Advertising
background image

26

About Your System

E1313

Fan redundancy

lost. Check

fans.

The system is no longer
fan redundant. Another
fan failure would put the
system at risk of
over-heating.

Check LCD for
additional scrolling
messages. See
"Troubleshooting a Fan"
on page 152.

E1410

Internal Error

detected.

Check "FRU X".

Specified processor has an
internal error. The error
may or may not have been
caused by the processor.

Remove AC power to the
system for 10 seconds and
restart the system.

If the problem persists,
see "Getting Help" on
page 167.

E1414

CPU # temp

exceeding

range. Check

CPU heatsink.

Specified processor is out
of acceptable temperature
range.

Ensure that the processor
heat sinks are properly
installed. See
"Troubleshooting the
Microprocessors" on
page 160 an
d
"Troubleshooting System
Cooling Problems" on
page 151.

E1418

CPU # not

detected.

Check CPU is

seated

properly.

Specified processor is
missing or bad, and the
system is in an
unsupported
configuration.

Ensure that the specified
microprocessor is
properly installed. See
"Troubleshooting the
Microprocessors" on
page 160.

E141C

Unsupported

CPU

configuration.

Check CPU or

BIOS revision.

Processors are in an
unsupported
configuration.

Ensure that your
processors match and
conform to the type
described in the processor
technical specifications
outlined in your system’s
Getting Started Guide.

Table 1-2.

LCD Status Messages (Optional) (continued)

Code

Text

Causes

Corrective Actions