Power supplies, Removing a redundant power supply – Dell PowerEdge R410 User Manual

Page 92

Advertising
background image

92

Installing System Components

Power Supplies

Your system supports the following power supply modules:

480W (non-redundant power supply)

500W (redundant power supply)

If two power supplies are installed, the second power supply provides hot-
swappable, power redundancy. In redundant mode, the system distributes the
power load across both power supplies to maximize efficiency. When a power
supply is removed with the system powered on, the full power load is picked
up by the remaining power supply.

Removing a Redundant Power Supply

CAUTION:

The system requires one power supply to operate the system normally.

On power-redundant systems, remove and replace only one power supply at a time
in a system that is powered on.

1 Disconnect the power cable from the power source.
2 Disconnect the power cable from the power supply and remove the Velcro

straps that bundle and secure the system cables.

NOTE:

You may have to unlatch and lift the optional cable management arm if

it interferes with power-supply removal. For information about the cable
management arm, see the system’s rack documentation.

3 Pull the power supply straight out to release it from the power distribution

board and clear the chassis.