Dell PowerEdge R410 User Manual

Page 52

Advertising
background image

52

About Your System

Unsupported

memory

configuration.

DIMM mismatch

across slots

detected:

x,x,...

Invalid memory
configuration.
Memory modules are
mismatched in the
specified slots.

Ensure that the memory
modules are installed in a
valid configuration.
See "General Memory
Module Installation
Guidelines" on page 119.

Unused memory

detected. DIMM’s

installed in the

following slot

are not available

when in mirror

mode:

x,x,x

The memory configuration
is not optimal for
mirroring Mode. Modules
in the specified slots are
unused.

Reconfigure the memory for
Memory Mirroring Mode, or
change the memory mode to
Optimized or Sparing in the
BIOS setup screen. See
"System Memory" on
page 119.

Unused memory

detected. DIMM’s

installed in the

following slot

are not available

when in 128-bit

advanced ECC

mode:

x,x,x

The memory configuration is
not optimal for Advanced
ECC Memory Mode.
Modules in the specified
slots are unused.

Reconfigure the memory for
Advanced ECC Memory
Mode, or change the
memory mode to Optimized
or Sparing in the BIOS setup
screen. See "System
Memory" on page 119.

Warning: A fatal

error has caused

system reset!

Please check the

system event log!

A fatal system error occurred
and caused the system to
reboot.

Check the SEL for
information that was logged
during the error. See the
applicable troubleshooting
section in "Troubleshooting
Your System" on page 145 for
any faulty components
specified in the SEL.

Table 1-3.

System Messages (continued)

Message

Causes

Corrective Actions

book.book Page 52 Tuesday, March 31, 2009 5:26 PM