Dell PowerEdge R410 User Manual

Page 31

Advertising
background image

About Your System

31

E1A15

SAS cable B

failure. Check

connection.

SAS cable B is missing
or bad.

Reseat the cable. If the
problem persists,
replace cable.

If the problem persists,
see "Getting Help" on
page 167.

E1A1D

Control panel

USB cable not

detected.

Check cable.

USB cable to the control
panel is missing or bad.

Reseat the cable. If the
problem persists, replace
cable.

If the problem persists,
see "Getting Help" on
page 167.

E2010

Memory not

detected.

Inspect DIMMs.

No memory was detected
in the system.

Install memory or reseat
memory modules. See
"Installing Memory
Modules" on page 123 or
"Troubleshooting System
Memory" on page 152.

E2011

Memory

configuration

failure.

Check DIMMs.

Memory detected, but is
not configurable.
Error detected during
memory configuration.

See "Troubleshooting
System Memory" on
page 152.

E2012

Memory

configured but

unusable.

Check DIMMs.

Memory configured, but is
unusable.

See "Troubleshooting
System Memory" on
page 152.

E2013

BIOS unable to

shadow memory.

Check DIMMs.

The system BIOS failed to
copy its flash image into
memory.

See "Troubleshooting
System Memory" on
page 152.

E2014

CMOS RAM

failure. Power

cycle AC.

CMOS failure. CMOS
RAM not functioning
properly.

Remove AC power to the
system for 10 seconds and
restart the system.

If the problem persists,
see "Getting Help" on
page 167.

Table 1-2.

LCD Status Messages (Optional) (continued)

Code

Text

Causes

Corrective Actions

book.book Page 31 Tuesday, March 31, 2009 5:26 PM