29

E1710

I/O channel

check error.

Review & clear

SEL.

The system BIOS has
reported an I/O channel
check.

Check the SEL for more
information and then
clear the SEL. Remove
AC power to the system
for 10 seconds and restart
the system.

If the problem persists,
see "Getting Help" on
page 167.

E1711

PCI parity

error on Bus

## Device ##

Function ##

The system BIOS has
reported a PCI parity
error on a component
that resides in PCI
configuration space at
bus ##, device ##,
function ##.

Remove and reseat the
PCIe expansion cards.
If the problem persists,
see "Troubleshooting
Expansion Cards" on
page 159.

PCI parity

error on Slot

#. Review &

clear SEL.

The system BIOS has
reported a PCI parity
error on a component
that resides in the
specified slot.

Remove and reseat the
PCIe expansion cards.
If the problem persists,
see "Troubleshooting
Expansion Cards" on
page 159.

E1712

PCI system

error on Bus

## Device ##

Function ##

The system BIOS has
reported a PCI system
error on a component
that resides in PCI
configuration space at
bus ##, device ##,
function ##.

Remove and reseat the
PCIe expansion cards.
If the problem persists,
see "Troubleshooting
Expansion Cards" on
page 159.

Table 1-2.

LCD Status Messages (Optional) (continued)

Code

Text

Causes

Corrective Actions

book.book Page 29 Tuesday, March 31, 2009 5:26 PM