Dell PowerEdge R410 User Manual

Page 30

Advertising
background image

30

About Your System

E1714

Unknown error.

Review & clear

SEL.

The system BIOS has
determined there has
been an error in the
system, but is unable to
determine its origin.

Check the SEL for more
information and then
clear the SEL. Remove
AC power to the system
for 10 seconds and restart
the system.

If the problem persists,
see "Getting Help" on
page 167.

E171F

PCIe fatal

error on Bus

## Device ##

Function ##

The system BIOS has
reported a PCIe fatal
error on a component
that resides in PCI
configuration space at
bus ##, device ##,
function ##.

Remove and reseat the
PCIe expansion cards.
If the problem persists,
see "Troubleshooting
Expansion Cards" on
page 159.

E1810

Hard drive ##

fault. Review

& clear SEL.

The specified hard drive
has experienced a fault.

See "Troubleshooting a
Hard Drive" on page 156.

E1812

Hard drive ##

removed. Check

drive.

The specified hard
drive has been removed
from the system.

Information only.

E1920

iDRAC6 Upgrade

Failed.

optional iDRAC6
upgrade has failed.

See "Troubleshooting
Expansion Cards" on
page 159.

E1A14

SAS cable A

failure. Check

connection.

SAS cable A is missing
or bad.

Reseat the cable. If the
problem persists,
replace cable.

If the problem persists,
see "Getting Help" on
page 167.

Table 1-2.

LCD Status Messages (Optional) (continued)

Code

Text

Causes

Corrective Actions

book.book Page 30 Tuesday, March 31, 2009 5:26 PM

Advertising