2.1.9

speed all

This command sets the speed and duplex setting for all interfaces.

Format

speed all

{<100 | 10> <half-duplex | full-duplex>}

Mode

Global Config

Acceptable values are:

100h

100BASE-T half-duplex

100f

100BASE-T full duplex

10h

10BASE-T half duplex

10f

10BASE-T full duplex

2.1.10

block

This command sets a port in blocking mode. A blocking port will not receive or
forward data frames. The command is only allowed if no spanning tree is enabled
because the spanning tree is setting the port states itself. If the port is currently
disabled, the state is not changed until it will become enabled. The state of the ports
can be listed (spanning tree) by using:

show spanning-tree mst port summary 0 all

Format

block

Mode

Interface Config

2.1.10.1

no block

This command resets a port in non-blocking mode.

Format

no block

Mode

Interface Config

2.1.11

show port

This command displays port information.

Format

show port

{<slot/port> | all}

Mode

Privileged EXEC

Interface

Valid slot and port number separated by forward slashes.

Type

If not blank, this field indicates that this port is a special type of port.
The possible values are:
Mirror - this port is a monitoring port. For more information, see 2.13
“Port Mirroring” on page 2 - 56
.
PC Mbr- this port is a member of a port-channel (LAG).
Probe - this port is a probe port.

Admin Mode The Port control administration state. The port must be enabled in

order for it to be allowed into the network. - May be enabled or dis-
abled. The factory default is enabled.