2 set gmrp interfacemode, 3 show gmrp configuration, Set gmrp interfacemode - 36 – Kontron AT8402 CLI User Manual
Page 68: Show gmrp configuration - 36, Switching commands at8402
Switching Commands
AT8402
AT8402 CLI Reference Manual
Page 2 - 36
2.9.1.1
no set gmrp adminmode
This command disables GARP Multicast Registration Protocol (GMRP) on the system.
Format
no set gmrp adminmode
Mode
Privileged EXEC
2.9.2
set gmrp interfacemode
This command enables GARP Multicast Registration Protocol on a single interface
(Interface Config mode) or all interfaces (Global Config mode). If an interface which
has GARP enabled is enabled for routing or is enlisted as a member of a port-channel
(LAG), GARP functionality is disabled on that interface. GARP functionality is
subsequently re-enabled if routing is disabled and port-channel (LAG) membership is
removed from an interface that has GARP enabled.
Default
disabled
Format
set gmrp interfacemode
Modes
Interface Config
Global Config
2.9.2.1
no set gmrp interfacemode
This command disables GARP Multicast Registration Protocol on a single interface or
all interfaces. If an interface which has GARP enabled is enabled for routing or is
enlisted as a member of a port-channel (LAG), GARP functionality is disabled. GARP
functionality is subsequently re-enabled if routing is disabled and port-channel (LAG)
membership is removed from an interface that has GARP enabled.
Format
no set gmrp interfacemode
Modes
Interface Config
Global Config
2.9.3
show gmrp configuration
This command displays Generic Attributes Registration Protocol (GARP) information
for one or all interfaces.
Format
show gmrp configuration
{<slot/port> | all}
Modes
Privileged EXEC
User EXEC
Interface
The slot/port
of the interface that this row in the table describes.
Join Timer The interval between the transmission of GARP PDUs registering (or
re-registering) membership for an attribute. Current attributes are a
VLAN or multicast group. There is an instance of this timer on a per-
port, per-GARP participant basis. Permissible values are 10 to 100
centiseconds (0.1 to 1.0 seconds). The factory default is 20 centisec-
onds (0.2 seconds). The finest granularity of specification is 1 centi-
second (0.01 seconds).