2-1 Installation and Connection to Sensor Amplifiers

2-4

- DeviceNet Compatible Network Unit DL-DN1 User's Manual -

2

Con

nect

io

n a

nd

Co
nf

igu
rat

ion

2

To remove the DL-DN1, raise the main unit in the direction of arrow (3)
while pushing it the direction of arrow (1).

„Procedures for connecting to sensor amplifiers

The DeviceNet compatible communication unit DL-DN1 must be connected to sensor
amplifiers before it can function.
The connecting procedure varies with the mounting type of the sensor amplifiers to be
connected.

For the instructions on connecting additional sensor amplifiers, refer
to the instruction manual of the sensors amplifiers.

Connecting to sensor amplifiers (DIN rail mounting type)

1

Remove the expansion protective cover from the sensor amplifier to be
connected.

2

Install the DeviceNet compatible communication unit, DL-DN1, on the DIN
rail and connect to the sensor amplifier.

Ensure a tight connection, leaving no space between the DeviceNet compatible
communication unit, DL-DN1, and the sensor amplifier.

Make sure that the power to the sensor amplifier is off before starting to
connect the DeviceNet compatible communication unit, DL-DN1. Per-
forming the procedure with the power on may damage the DL-DN1.

NOTICE

Point

Sensor amplifier

Expansion protective cover

Sensor amplifier

DeviceNet compatible communication
unit DL-DN1

Connector