2 wiring, Connecting to the devicenet, Wiring -7 – KEYENCE DL-DN1 User Manual

Page 23: Connecting to the devicenet -7, Wiring

Advertising
background image

2-7

2

Con

nect

io

n a

nd

Co
nf

igu
rat

ion

- DeviceNet Compatible Network Unit DL-DN1 User's Manual -

2-2

Wiring

This section describes how to wire the DL-DN1.
Refer also to the DeviceNet Installation Manual published by ODVA.

Turn off the power before wiring.

Use the following procedure to connect the DL-DN1 to the DeviceNet.

„Recommended cables

For connection between the DL-DN1 and the DeviceNet, use a dedicated DeviceNet
cable conforming to the DeviceNet specifications or a dedicated flat cable.

Do not use non-dedicated cables, as this may inhibit proper commu-
nication.

„Trimming the cable

1

Strip the cable sheath.

Strip approximately 70 mm of cable sheath.
Make sure that the bare part of the shield braid is 6 mm or shorter.

Point

Connecting to the DeviceNet

Point

6 mm or shorter

Approx. 70 mm

Shield braid

Sheath

Advertising