3-3 Explicit Messaging

3-27

- DeviceNet Compatible Network Unit DL-DN1 User's Manual -

3

Comm

un
ica
ti

ng wit

h th

e

IB

Ser

ies

*1

"Status details" (page 3-7)

*2

"Error information list" (page 3-8)

0

69 to 6B System reserved

6C

Error ID number Error details.

If there are errors with multiple ID
numbers, the error information for the
smallest error code is output.

R

UINT

0

*2

6D

Error code

R

UINT

0

6E

Warning ID
number

Warning details.
If there are errors with multiple ID
numbers, the warning information for
the smallest ID number is output.

R

UINT

0

*3

6F

Warning code

R

UINT

0

70 to 73 System reserved

74

HIGH

The HIGH state is output by assigning
sensor amplifiers (ID 01 to ID 04) bits
0 - 3.

R

WORD

0

0: OFF
1: ON

75

LOW

The LOW state is output by assigning
sensor amplifiers (ID 01 to ID 04) bits
0 - 3.

R

WORD

0

0: OFF
1: ON

76

GO

The GO state is output by assigning
sensor amplifiers (ID 01 to ID 04) bits
0 - 3.

R

WORD

0

0: OFF
1: ON

77

Check output

The check output is output by assign-
ing sensor amplifiers (ID 01 to ID 04)
bits 0 - 3.

R

WORD

0

0: OFF
1: ON

78

(Not used)

79 to 8C System reserved

8D

Measured value
"invalid"

If the measured values for sensor
amplifiers (ID 01 to ID 04) are "invalid"
(-----), they are output by assigning
them to bits 0 - 3.

R

WORD

0

0: Normal value
1: Invalid

8E

Measured value
"under"

If the measured values for sensor
amplifiers (ID 01 to ID 04) are "under,"
they are output by assigning them to
bits 0 - 3.

R

WORD

0

0: Normal value
1: Under

8F

Measured value
"over"

If the measured values for sensor
amplifiers (ID 01 to ID 04) are "over,"
they are output by assigning them to
bits 0 - 3.

R

WORD

0

0: Normal value
1: Over

90

Current value ID
01

Reads the current value of ID 01.
Same as the current value used in I/O
communication.

R

DINT32

0

-2147483648 to
2147483647

~

93

Current value ID
04

Reads the current value of ID 04.
Same as the current value used in I/O
communication.

9F to B0 System reserved

B1

Number of
sensor amplifier
units connected

Reads the number of connected sen-
sor amplifiers.

R

UINT

0

1 to 4

B2 to B3 System reserved

B4

Explicit message
response method

If synchronous response is used,
response occurs synchronously with I/
O communication.

R/W

UINT

0

0: Immediate
response
1: Synchronous
response

B5 to B9 System reserved

BA

Operating mode
switch status

Set status of operating mode setting
switch: switch 1 (LSB) to switch 4
(MSB)

R

UINT

0

0 to 15
0: OFF, 1: ON

InstID
(DEC)

AttrID

(HEX)

Name

Description

Attribute

Data

type

Default

value

Parameter range