Changing a bank, 2 i/o communication – KEYENCE DL-DN1 User Manual

Page 40

Advertising
background image

3-2 I/O Communication

3-12

- DeviceNet Compatible Network Unit DL-DN1 User's Manual -

3

Comm

un
ica
ti

ng wit

h th

e

IB

Ser

ies

IN area

n: The first device number assigned to the DL-DN1
The device assignments are the same for all 5-output modes including extended
modes.

Changing a BANK

Sensor amplifier ID numbers 01 to 04 are assigned to bits 0 to 3, respectively.

For details of communication methods, see

"Changing the BANK number of

sensor amplifiers" (page 3-18).

„3-output mode

OUT area

m: The first device number assigned to the DL-DN1

IN area

n: The first device number assigned to the DL-DN1
The device assignments are the same for all 3-output modes including extended
modes.

Device

(DEC)

Name

Bit 7

Bit 6

...

Bit 1

Bit 0

Bit 15

Bit 14

...

Bit 9

Bit 8

n+6

External input-1 response

ID08

ID07

...

ID02

ID01

Reserved

ID15

...

ID10

ID09

n+7

External input-2 response

ID08

ID07

...

ID02

ID01

Reserved

ID15

...

ID10

ID09

n+8

External input-3 response

ID08

ID07

...

ID02

ID01

Reserved

ID15

...

ID10

ID09

n+9

External input-4 response

ID08

ID07

...

ID02

ID01

Reserved

ID15

...

ID10

ID09

n+10

Reserved

ID08

ID07

...

ID02

ID01

Reserved

ID15

...

ID10

ID09

Device

(DEC)

Name

Bit 7

Bit 6

...

Bit 1

Bit 0

Bit 15

Bit 14

...

Bit 9

Bit 8

m+3

Request to change BANK

ID08

ID07

...

ID02

ID01

Reserved

ID15

...

ID10

ID09

m+4

Select BANK number

Specifies a new BANK number

(2-byte unsigned integer; range: 0-3).

Device

(DEC)

Name

Bit 7

Bit 6

...

Bit 1

Bit 0

Bit 15

Bit 14

...

Bit 9

Bit 8

n+7

BANK change complete

ID08

ID07

...

ID02

ID01

Reserved

ID15

...

ID10

ID09

n+8

BANK change error

ID08

ID07

...

ID02

ID01

Reserved

ID15

...

ID10

ID09

Advertising