„Error information list

Error

ID No.

Error
code

(HEX)

Description

Cause

Corrective action

00h

01h

Initialization error

Error encountered during initial-
ization.

Check the number of con-
nected sensor amplifiers and
the connection to the sensor
amplifiers, and then turn off the
power and back on. If the error
cannot be recovered, contact
your nearest sales office.

04h

Mixed connection error

A foreign sensor amplifier (i.e.,
one that cannot be intermixed)
is connected.

Remove the foreign sensor
amplifier.

See

"Mixed Connection of

Sensor Amplifiers" (page 5-3).

06h

Number-of-units error

More sensor amplifiers are con-
nected than are permitted.

Observe the number of con-
nectable sensor amplifiers.

nn㪿

(㪇㪈㪿㩷㫋㫆㩷

㪇㪝㪿)

01h

Error 1 for sensor amplifier of
ID number nn

Overcurrent Error

Refer to the IB series user's
manual.

02h

Error 2 for sensor amplifier of
ID number nn

EEPROM Error

03h

Error 3 for sensor amplifier of
ID number nn

Head error (light transmitter/
receiver)

04h

Error 4 for sensor amplifier of
ID number nn

Transmitter/Receiver reverse
connection error

05h

Error 5 for sensor amplifier of
ID number nn

Light emitter internal error

06h

Error 6 for sensor amplifier of
ID number nn

Light receiver error

07h

Error 7 for sensor amplifier of
ID number nn

Light transmitter error

08h

Error 8 for sensor amplifier of
ID number nn

Light transmitter laser error

09h

Error 9 for sensor amplifier of
ID number nn

Model mismatch error

0Ah

Error 10 for sensor amplifier of
ID number nn

Reference light intensity regis-
tration error

0Bh

Error 11 for sensor amplifier of
ID number nn

Adjust error

0Ch

Error 12 for sensor amplifier of
ID number nn

Amp-to-Amp communicaion
error

1Dh

02h/04
to 07h

System error

An error occurred in the internal
system.

Check the connection to the
sensor, and then turn off the
power and back on. If the error
cannot be recovered, contact
your nearest sales office.

03h

Model error

There is connected a sensor
amplifier of a model incompati-
ble with the DL-DN1.

Connect a sensor amplifier of a
compatible model.

1Fh

-

No error

-

-

Advertising