3-1 Overview of DeviceNet Communication

3-3

- DeviceNet Compatible Network Unit DL-DN1 User's Manual -

3

Comm

un
ica
ti

ng wit

h th

e

IB

Ser

ies

The master unit of the DeviceNet system can use the following functions:

*

When using these functions in explicit messaging, use the command parameters

for the functions assigned to external inputs 1 to 5. For details, see

"Command

parameter list for IB series" (page 3-28)

„I/O Communication

• The output signal, comparator value, and error status of sensor amplifiers can be

communicated without the need of a ladder program.

• By using the IN and OUT areas as handshake signals, the master unit can execute

external inputs to the sensor amplifier or change setting values.

"I/O Communication" (page 3-4)

„Explicit Messaging

The master unit can use explicit messaging commands to directly read/write
parameter values of sensor amplifiers. All functions that can be executed on sensor
amplifiers are available through explicit messaging.

"Explicit Messaging" (page 3-20)

Overview of Communication Methods

Function of

sensor amplifier

Communication methods

I/O communication

p. 3-4

Explicit messaging

p. 3-20

Read status

Yes

Yes

Read output 1to 5

Read current value

Execute external input 1to 5*

Change BANK number

Rewrite setting value

Motion command

No

Read current value, setting,
and status

Read data with decimal
point information

Rewrite setting

Lock all