1 specifications, Specifications -2, Specifications – KEYENCE DL-DN1 User Manual

Page 68: Spec if ica ti ons

Advertising
background image

4-2

- DeviceNet Compatible Network Unit DL-DN1 User's Manual -

4

Spec

if

ica
ti

ons

4-1

Specifications

*1

"D-bus" is the name of KEYENCE's wiring-saving system for sensor amplifiers.

*2

Depends on the type of sensor amplifiers connected.

Product name

DeviceNet compatible communication unit

Model

DL-DN1

Communication method

DeviceNet compliant

DeviceNet specifi-
cations

Compliant functions

Remote I/O communication (polling)
Explicit messaging

Address setting

0 to 63 (PGM compatible)

Baud rate
(automatically switched)

500 kbps/250 kbps/125 kbps

Maximum cable
length

500 kbps

100 m for thick cable; 100 m for thin cable

250 kbps

250 m for thick cable; 100 m for thin cable

125 kbps

500 m for thick cable; 100 m for thin cable

Network power supply

11 to 25 VDC (supplied from DeviceNet communication power sup-
ply)

Sensor connection
specifications

Connectable sensors

Sensor amplifiers with D-bus support

*1

Number of connectable sensor
units

15 units max.

*2

Indicators

Network status indicator: 2-color (green/red) LED
Module status indicator: 2-color (green/red) LED
Sensor communication indicator: 2-color (green/red) LED

Power voltage

20 to 30 VDC, including ripple (P-P) 10%
(supplied from the connected sensor amplifiers)

Power consumption

660 mW or less (at 30 V, 22 mA max.)

Environmental
resistance

Operating ambient temperature -20 to +55°C (no freezing)
Operating ambient humidity

35 to 85% RH (no condensation)

Vibration resistance

10 to 55 Hz, compound amplitude 1.5 mm, 2 hours each in X, Y, Z
directions

Pollution degree

2

Materials

Main unit case and dust cover: Polycarbonate
DeviceNet connector: Polyamide (plug), PUT (socket)

Weight (including connectors)

Approx. 80g

Advertising