Selecting an operating mode of the dl-cl1, Selecting an operating mode of the dl-cl1 -3, 1 cc-link communication and operating modes – KEYENCE DL-CL1 User Manual

Page 31: Co mm u ni c a ting w ith t he fd -m h s er ie s

Advertising
background image

3-1 CC-Link Communication and Operating Modes

3-3

3

Co
mm

u

ni

c

a

ting
w

ith t
he FD

-M

H

s

er

ie

s

- CC-Link Compatible Network Unit DL-CL1 User’s Manual (FD-MH) -

Select an operating mode of the DL-CL1 to suit the functions of the sensor amplifiers
to be used.
The specific CC-Link device configuration and the data that can be communicated
using cyclic transfer vary with each operating mode of the DL-CL1. An appropriate
operating mode should be determined by considering the number of link points the
data that can be communicated.

"Configuring the Data Link" (page 2-10)

Yes: Available with sensor amplifiers of ID 01 to 10. No: Not available.

*1

For details of the functions assigned for motions commands and setting/status read/write, see

"Device Maps" (page 3-4) and

"Command Parameter List" (page 3-24).

*2

In remote register RWw, specify the ID number of the sensor amplifier from which to read.

*3

To use this communication method, create a program that controls commands by handshaking
between a remote input/output and remote register.

*4

It is possible to read instantaneous flow rate or rewrite setting value regardless of the detection
mode setting.

Selecting an Operating Mode of the DL-CL1

Method of

communication
with the master

station

Available function

of sensor

amplifier

*1

Operating mode of DL-CL1

Reference

page for

communication

method

Small-

memory

mode 1

Small-

memory

mode 2

Monitor

mode 1

Monitor

mode 2

Full

mode 1

Full

mode 2

1-station,

1x

2-station,

1x

4-station,

1x

1-station,

8x

4-station,

2x

2-station,

8x

p. 3-4

p. 3-10

Remote input RX

Read out-
puts 1 - 5

Output 1

Yes

Yes

Yes

Yes

Yes

Yes

3-4

Output 2

No

Yes

Yes

Yes

Yes

Yes

Output 3

No

Yes

Yes

Yes

Yes

Yes

Unused

-

-

-

-

-

-

Unused

-

-

-

-

-

-

Remote register RWr

Read current value
(instantaneous flow

rate)

*4

No

No

Yes

*2

Yes

Yes

Yes

3-6

Remote output RY

External
inputs 1-5

Integration
reset

Yes

Yes

Yes

Yes

Yes

Yes

3-12

Flow rate
hold reset

No

Yes

Yes

Yes

Yes

Yes

Unused

-

-

-

-

-

-

Tempera-
ture hold
reset

No

No

Yes

Yes

Yes

Yes

Unused

-

-

-

-

-

-

Remote register
RWw

Rewrite setting

value

*4

No

No

No

No

Yes

Yes

3-16

Handshake control

program

*3

(Command commu-
nication)

Motion command

No

No

Yes

Yes

Yes

Yes

3-20

Read output

No

No

Yes

Yes

Yes

Yes

3-17

Read current value

Read setting/status

Write setting/status