3-4 Command Parameter List

3-26

- CC-Link Compatible Network Unit DL-CL1 User’s Manual (FD-MH) -

Co
mm

u

ni

c

a

ting
w

ith t
he FD

-M

H

s

er

ie

s

3

The following tables provide command parameters for the FD-MH series. The two
types of parameters are: motion command parameters and setting/status command
parameters.

Motion command parameters

For the communication methods using motion command parameters, see

"Issuing

a Motion Command to a Sensor Amplifier" (page 3-20).
Attribute R: Read; C: Motion command
nn: ID number of sensor amplifier. Example: For nn05h and ID13, then 0D05h.

Setting/status command parameters

For the communication methods using setting/status parameters, see

"Reading/

Writing Settings or Status of a Sensor Amplifier" (page 3-21).
Attribute R: Read; W: Write; R/W: Read/Write
nn: ID number of sensor amplifier. Example: For nn41h and ID13, then 0D41h.
The data type is DINT (32-bit singed integer).

Command Parameter List for FD-MH Series

Data

category

(HEX)

Data

number

(HEX)

Name

Description

Attribute

00

nn00

Group-0 entry count

The default vaule is 5.

R

nn01

System reserved

nn02

Integrated fl ow quantity reset
request

Resets integrated fl ow quantity.

C

nn03

Reset request during hold
(instantaneous fl ow rate)

Resets instantaneous fl ow hold value.

C

nn04

Reset request during hold
(temperature display)

Resets temperature hold value.

C

nn05

Initial reset request (ALL)

Resets all settings of the sensor amplifi er to
the factory default settings.

C

Data

category

(HEX)

Data

number

(HEX)

Name

Description

Attribute

Sensor head

Default

value

Parameter range

00

nn20

Group-1 entry
count

R

-

22

nn21

Sensor amplifier
error state

*1

R

-

-

Bit 0: Head error (ErS)
Bit 1: Head connection error (ErH)
Bit 2: Overcurrent error (ErC)
Bit 3: EEPROM error (ErE)
Bit 4: Always 0
Bit 5: Always 0
Bit 6: Backflow error (rEv)
Bit 7: Always 0
Bit 8: Temperature lower limit error
Bit 8: Temperature upper limit error
Bit 10: Temperature sensor connection
error (Err tEMP)
Bits 11 to 15: Always 0

nn22

System reserved

nn23

System reserved

Advertising