4 command parameter list, Common command parameter list, Command parameter list -24 – KEYENCE DL-CL1 User Manual

Page 52: Common command parameter list -24, Command, Command parameter list, Co mm u ni c a ting w ith t he fd -m h s er ie s

Advertising
background image

3-24

3

Co
mm

u

ni

c

a

ting
w

ith t
he FD

-M

H

s

er

ie

s

- CC-Link Compatible Network Unit DL-CL1 User’s Manual (FD-MH) -

3-4

Command Parameter List

The following tables list the command parameters used to read/write the settings and
status of sensor amplifiers, or to issue motion commands, by creating a handshake
control program.
For details about how the master station communicates using command parameters,
see:

"Issuing a Motion Command to a Sensor Amplifier" (page 3-20)

"Reading/Writing Settings or Status of a Sensor Amplifier" (page 3-21)

The table below describes parameters which are common to the DL-CL1.

For the communication methods using these common command parameters, see
"Reading/Writing Settings or Status of a Sensor Amplifier" (page 3-21).
Attribute R: Write; W: Read

Common Command Parameter List

Data

category

(HEX)

Data

number

(HEX)

Name

Description

Attribute

Data

type

Default

value

Parameter range

00

** 00 to

** FF

*3

01

0000

All unit key
lock

Activates key lock on all sensor
amplifi ers connected.

W

UINT

0

0: Unlock
1: Full key lock
2: Key lock

03

0000

Error
information

Possible errors, and their contents, of
sensor amplifi ers
Same content as remote register
(RWr[n] + 0)
If there are errors with multiple ID
numbers, the error information for the
smallest ID number is reported.

R

UINT

0

*4

0001

Warning
information

Not used with the FD-MH series.

-

-

-

0002

Error ID
number

*3

Errors are read by assigning sensor
amplifi ers (ID 01 to ID 10) to bits 0 - 9.
If there are errors with multiple ID
numbers, all of the associated bits
are set to 1.The error with DL-CL1 is
assigned to bit 15.

WORD

0

For each bit
0: No Error
1: Error

0003

Warning ID
number

Not used with the FD-MH series.

-

-

-

0101

Output ID
01

Output state of ID 01.
Each output is assigned to the
corresponding bit.

*1

Same content as remote input RX.

WORD

0

For each bit
0: Output OFF
1: Output ON

···

···

010A

Output ID
01

Output state of ID 10.
Each output is assigned to the
corresponding bit.

*1

Same content as remote input RX.

0201

Current
Value ID01

Reads the instantaneous fl ow rate
value of ID01.
Same content as the instantaneous
fl ow rate value in remote register RWr.

DINT

0

···

···

0213

Current
Value ID10

Reads the instantaneous fl ow rate
value of ID10.
Same content as the instantaneous
fl ow rate value in remote register RWr.

Advertising