Data Processing Times
This section describes the length of time taken from detection by a sensor(s) to data
processing by PLC.
Maximum data processing time = (1) + (2) x 2 + (3) + (4)
(1) PLC scan time
(2) Network scan time
(3) Data communication time of DL-CL1
(4) Response time of sensor amplifier
(3) Data communication time of DL-CL1
The lengths of time taken for the data of output or current value to be sent from a
sensor amplifier to the DL-CL1 are summarized below.
For information on (1), (2), and (4), refer to the manual of each unit.
Number of sensor amplifier units connected
Output, judgment value, or current value
1
9 ms
2
11 ms
3
15 ms
4
17 ms
5
21 ms
6
23 ms
7
27 ms
8
29 ms
9
33 ms
10
35 ms
CPU unit
CC-Link
master unit
DL-CL1
Sensor amplifier
(1)
(2)
(3)
(4)