3-2 Device Maps

3-14

- CC-Link Compatible Network Unit DL-CL1 User’s Manual (FD-MH) -

Co
mm

u

ni

c

a

ting
w

ith t
he FD

-M

H

s

er

ie

s

3

Number [n] denotes the first relay number assigned to the DL-CL1.

*1

See

"Entering an External Input into a Sensor Amplifier" (page 3-17).

*2

See

"Reading/Writing Settings or Status of a Sensor Amplifier" (page 3-21).

See

"Issuing a Motion Command to a Sensor Amplifier" (page 3-20).

*3

See

"Rewriting a Setting Value of a Sensor Amplifier" (page 3-21).

Remote Register RWr (DL-CL1 -> Master Station)

Operating

mode

Device no.

(HEX)

Name

Communication

method

Description

Reading range

Monitor mode

2

Full mode

1

Full mode

2

RWr[n] + 00 Error code

-

Stores an error code when error state (RX[n]
+ 0F) turns ON.

*4

RWr[n] + 01

Command
response

*2

Used when communicating under handshake
control program.
Stores details of command execution result.

*5

RWr[n] + 02
to 03
(2 words)

Read data

*2

Used when communicating under handshake
control program.
Stores the parameter data read from the
sensor amplifi er.

The data type
depends on the
parameter type.

RWr[n] + 04

Integration reset
input response

*1

Stores the integration reset input response of
the sensor amplifi er.
The response is output by assigning sensor
amplifi ers (ID 01 to ID 10) to bits 0 - 9.

0: Input OFF
1: Input ON

RWr[n] + 05

Flow rate hold
reset input
response

*1

Stores the fl ow rate hold reset input response
of the sensor amplifi er.
The response is output by assigning sensor
amplifi ers (ID 01 to ID 10) to bits 0 - 9.

0: Input OFF
1: Input ON

RWr[n] + 06 (Not used)

-

-

-

RWr[n] + 07

Temperature
hold reset input
response

*1

Stores the temperature hold reset input
response of the sensor amplifi er.
The response is output by assigning sensor
amplifi ers (ID 01 to ID 10) to bits 0 - 9.

0: Input OFF
1: Input ON

RWr[n] + 08 (Not used)

-

-

-

RWr[n] + 09

Current value
"invalid"

*3

If instantaneous fl ow rates from sensor
amplifi ers (ID 01 to ID 10) are invalid (-----),
they are output by assigning them to bits 0 - 9.

0: Normal value
1: Invalid

RWr[n] + 0A

Current value
"over"

*3

If instantaneous fl ow rates from sensor
amplifi ers (ID 01 to ID 10) are "over"(FFFF),
they are output by assigning them to bits 0 - 9.

0: Normal value
1: Over

RWr[n] + 0B

Current value
"under"

*3

Not used with the FD-MH series.

-

RWr[n] +0C
to 0D
(INT32)

Current Value
ID01

*3

Used for reading the instantaneous fl ow rate
value.
Outputs the instantaneous fl ow rate value of
the sensor amplifi er (ID 01).

INT32 (LITTLE)

RWr[n] +0E
to 0F
(INT32)

Current Value
ID02

*3

Used for reading the instantaneous fl ow rate
value.
Outputs the instantaneous fl ow rate value of
the sensor amplifi er (ID 02).

INT32 (LITTLE)

RWr[n] +10
to 11
(INT32)

Current Value
ID03

*3

Used for reading the instantaneous fl ow rate
value.
Outputs the instantaneous fl ow rate value of
the sensor amplifi er (ID 03).

INT32 (LITTLE)