KEYENCE LJ-V7000 Series User Manual

Page 73

Advertising
background image

73

LJ-V7000_COM_RM_E

• Position correction settings

<Dual head mode>

Type:10h~1Fh (10h:Program NO.0, 11h:Program NO.1,

, 1F:Program NO.15)

Category:04h, Item:01h
Target1~4:00h

byte

Setting Data

0

Dual head mode:

0:OFF, 1:ON

1

Reserved (fixed as 0)

2

Reserved (fixed as 0)

3

Reserved (fixed as 0)

Note: This setting is not used when one sensor head.

<Dual head mode target head>

Type:10h~1Fh (10h:Program NO.0, 11h:Program NO.1,

, 1F:Program NO.15)

Category:04h, Item:02h
Target1~4:00h

byte

Setting Data

0

Correction target head: 0:headA, 1:headB

1

Reserved (fixed as 0)

2

Reserved (fixed as 0)

3

Reserved (fixed as 0)

Note: This setting is not used when one sensor head.

<Dual head mode X/Z correction amount>

Type:10h~1Fh (10h:Program NO.0, 11h:Program NO.1,

, 1F:Program NO.15)

Category:04h, Item:03h (X correction amount), 04h (Z
correctionamount)
Target1~4:00h

byte

Setting Data

0

Correction amount: -10000.0~+10000.0mm

(0.001μm unit, Sined 32-bit integer

example:1mm=100000, 2mm=200000)

1
2
3

Note: This setting is not used when one sensor head.

< correction ON/OFF><Backup correction ON/OFF>

Type:10h~1Fh (10h:Program NO.0, 11h:Program NO.1,

, 1F:Program NO.15)

Category:04h, Item:05h ( correctionON/OFF), 07h
(preliminary correctionON/OFF)
Target1:00h (headA/wide), 01h (headB)
Target2:00h (Position correction1), 01h (Position
correction2), Target3~4:00h

byte

Setting Data

0

ON/OFF: 0:OFF, 1:ON

1

Reserved (fixed as 0)

2

Reserved (fixed as 0)

3

Reserved (fixed as 0)

< correction detail>

Type:10h~1Fh (10h:Program NO.0, 11h:Program NO.1,

, 1F:Program NO.15)

Category:04h, Item:06h (correctionON/OFF)
Target1:00h (headA/wide), 01h (headB)
Target2:00h (position correction1), 01h (position
correction2), Target3~4:00h

byte

Setting Data

0

Linear calculation area: 0:Area 2 disabled, 1:Area2

enabled

1

Reserved (fixed as 0)

2

Reserved (fixed as 0)

3

Reserved (fixed as 0)

4

Linear calculation area1 Left: any value in

measurement range

(0.01μm unit Sined 32-bit integer

example: 5mm=500000)

5
6
7
8

Linear calculation area1 Right: any value in

measurement range

(0.01μm unit Sined 32-bit integer

example: 5mm=500000)

9

10
11
12

Linear calculation area2 Left: any value in

measurement range

(0.01μm unit Sined 32-bit integer

example: 5mm=500000)

13
14
15
16

Linear calculation area2 Right: any value in

measurement range

(0.01μm unit Sined 32-bit integer

example: 5mm=500000)

17
18
19
20

Correction standard: 0:Horizontal,1:MasterProfile

21

Reserved (fixed as 0)

22

Reserved (fixed as 0)

23

Reserved (fixed as 0)

<preliminary correction detail><Xcorrection detail>

Type:10h~1Fh (10h:Program NO.0, 11h:Program NO.1,

, 1F:Program NO.15)

Category:04h, Item:08h (preliminary correctiondetail), 0Bh
(Xcorrectiondetail)
Target1:00h (headA/wide), 01h (headB)
Target2:00h (position correction1), 01h (position
correction2), Target3~4:00h

byte

Setting Data

0

Edge measuring area Left: any value in

measurement range

(0.01μm unit Sined 32-bit integer

example: 5mm=500000)

1
2
3
4

Edge measuring area Right: any value in

measurement range

(0.01μm unit Sined 32-bit integer

example: 5mm=500000)

5
6
7
8

Edge direction: 0:Rising, 1:Falling

9

Detaction direction: 0:+direction, 1:–direction

10

Detection No: 1~10

11

Reserved (fixed as 0)

12

Edge level: any value in measurement range

(0.01μm unit Sined 32-bit integer

example: 5mm=500000)

13
14
15

Advertising