LJ-V7000_COM_RM_E

9:Area

byte

Setting Data

4

Measurement target head: 0: HeadA, 1: HeadB, 2:

Combined profile (only when profile combine (wide) is on)

5

Measurement reference selection: 0:Reference for 1 line,

1:Reference for 2 lines, 2:Master reference

6

Measurement target position correction: 0: No position

correction, 1: Position correction1, 2: Position correction2

7

Measurement target1 position correction: 0: No position

correction, 1: Position correction1, 2: Position correction2

8

Measurement target2 position correction: 0: No position

correction, 1: Position correction1, 2: Position correction2

9

Reserved (fixed as 0)

10

Reserved (fixed as 0)

11

Reserved (fixed as 0)

12

Measurement area Area calculation area Left: any

value in measurement range

(0.01μm unit Sined 32-bit integer

example: 5mm=500000)

13
14
15
16

Measurement area Area calculation area Right: any

value in measurement range

(0.01μm unit Sined 32-bit integer

example: 5mm=500000)

17
18
19
20

Linear calculation area: 0:Area2 disabled, 1:Area2 enabled

21

Reserved (fixed as 0)

22

Reserved (fixed as 0)

23

Reserved (fixed as 0)

24

Reference straight line1 Linear calculation area

Left: any value in measurement range

(0.01μm unit Sined 32-bit integer

example: 5mm=500000)

25
26
27
28

Reference straight line1 Linear calculation area

Right: any value in measurement range

(0.01μm unit Sined 32-bit integer

example: 5mm=500000)

29
30
31
32

Reference straight line1 Area2 Left: any value in

measurement range

(0.01μm unit Sined 32-bit integer

example: 5mm=500000)

33
34
35
36

Reference straight line1 Area2 Right: any value in

measurement range

(0.01μm unit Sined 32-bit integer

example: 5mm=500000)

37
38
39
40

Linear calculation area: 0:Area2 disabled, 1:Area2 enabled

41

Reserved (fixed as 0)

42

Reserved (fixed as 0)

43

Reserved (fixed as 0)

44

Reference straight line2 Linear calculation area

Left: any value in measurement range

(0.01μm unit Sined 32-bit integer

example: 5mm=500000)

45
46
47
48

Reference straight line2 Linear calculation area

Right: any value in measurement range

(0.01μm unit Sined 32-bit integer

example: 5mm=500000)

49
50
51
52

Reference straight line2 area2 Left: any value in

measurement range

(0.01μm unit Sined 32-bit integer

example: 5mm=500000)

53
54
55
56

Reference straight line2 area2 Right: any value in

measurement range

(0.01μm unit Sined 32-bit integer

example: 5mm=500000)

57
58
59
60

Reserved (fixed as 0)

~

91

* Reference straight line2’s settings are not needed when

Reference for 1 line is selected.

* Reference straight line1, 2’s settings are not needed

whenMaster Reference is selected.

10:Master comparison (Z)

byte

Setting Data

4

Measurement target head: 0: HeadA, 1: HeadB, 2:

Combined profile (only when profile combine

(wide) is on)

5

Position correction selection: 0: No position

correction, 1: Position correction1, 2: Position

correction2

6

Reserved (fixed as 0)

7

Reserved (fixed as 0)

8

Area setting Left: any value in measurement range

(0.01μm unit Sined 32-bit integer

example: 5mm=500000)

9

10
11
12

Area setting Right: any value in measurement

range

(0.01μm unit Sined 32-bit integer

example: 5mm=500000)

13
14
15
16

Reserved (fixed as 0)

~

91

11:Distance(point-point)

byte

Setting Data

4

Measurement target head: 0: HeadA, 1: HeadB, 2:

Combined profile (only when profile combine

(wide) is on)

5

Measurement target selection: 0:Peak, 1:Bottom,

2:Knee, 3:Intsect (lines), 4:Contact (lin-arc), 5:

Center of circle

6

Position correction selection: 0: No position

correction, 1: Position correction1, 2: Position

correction2

7

Reserved (fixed as 0)

8

Unique parameters are assigned to each

measurement target. For details on the unique

parameters, see "Measurement area details"

(page 83).

~

M

M+1

Reserved (fixed as 0)

~

47

48

Reference target selection: 0: HeadA, 1: HeadB, 2:

Combined profile (only when profile combine

(wide) is on)

49

Reference target selection: 0:Peak, 1:Bottom,

2:Knee, 3:Intsect (lines), 4:Contact (lin-arc),

5:Center of circle

50

Position correction selection: 0: No position

correction, 1: Position correction1, 2: Position

correction2

51

Reserved (fixed as 0)

52

Unique parameters are assigned to each

Reference target. For details on the unique

parameters, see "Measurement area details"

(page 83).

~

N

N+1

Reserved (fixed as 0)

~

91

Advertising