KEYENCE LJ-V7000 Series User Manual

Page 81

Advertising
background image

81

LJ-V7000_COM_RM_E

[Unique parameters of Measuring period from
4byte]

<Measurement valuefilter detail>

Type:10h~1Fh (10h:Program NO.0, 11h:Program NO.1,

, 1F:Program NO.15)

Category:06h, Item:06h
Target1:00h~0Fh (OUT1~16) Target2~4:00h
Unique parameters are assigned to each measurement

value filter.

1:Moving average

byte

Setting Data

0

Averagecount: 0:4 times, 1:16 times, 2:64 times,

3:256 times, 4:1024 times, 5:4096 times

1

Reserved (fixed as 0)

2

Reserved (fixed as 0)

3

Reserved (fixed as 0)

2:Low-pass filter
3:High-pass filter

byte

Setting Data

0

Cutoff frequency: 0:0.1Hz, 1:0.3Hz, 2:1Hz, 3:3Hz,

4:10Hz, 5:30Hz, 6:100Hz, 7:300Hz, 8:1000Hz

1

Reserved (fixed as 0)

2

Reserved (fixed as 0)

3

Reserved (fixed as 0)

<Scaling measurement value1><Scaling display value1>

<Scaling measurement value2><Scaling display value2>

Type:10h~1Fh (10h:Program NO.0, 11h:Program NO.1,

, 1F:Program NO.15)

Category:06h, Item:07h (Scaling measurement value1),

08h (Scaling display value1), 09h (Scaling measurement

value2), 0Ah (Scaling display value2)
Target1:00h~0Fh (OUT1~16) Target2~4:00h

byte

Setting Data

0

Measurement value/Display value: 0.01μm unit

Sined 32-bit integer.

*Display range lower limit for the minimum display

unit Measurement value/Display value Display

range upper limit for the minimum display unit.

1
2
3

<Measuring mode>

Type:10h~1Fh (10h:Program NO.0, 11h:Program NO.1,

, 1F:Program NO.15)

Category:06h, Item:0Bh
Target1:00h~0Fh (OUT1~16) Target2~4:00h

byte

Setting Data

0

Measuring mode: 0:Normal, 1:Peak hold, 2:bottom

hold, 3:Peak to Peak hold, 4:Average hold, 5:Sample

hold, 6:Peak, 7:bottom, 8:Peak to Peak, 9:Average

1

Reserved (fixed as 0)

2

Reserved (fixed as 0)

3

Reserved (fixed as 0)

<Measuring period>

Type:10h~1Fh (10h:Program NO.0, 11h:Program NO.1,

, 1F:Program NO.15)

Category:06h, Item:0Ch
Target1:00h~0Fh (OUT1~16) Target2~4:00h

byte

Setting Data

0

Measuring period: 0:Terminal/command,

1:Measurement area 2 :OUT reference,

3:Threshhold (level), 4:Threshhold (Edge)

1

Reserved (fixed as 0)

2

Reserved (fixed as 0)

3

Reserved (fixed as 0)

4

Unique parameters are assigned to each

measuring period. The unique parameters are

described below.

~

15

1:Measurement area

byte

Setting Data

4

Measure start position: value withinBatch point

5
6

Measure end position: value withinBatch point

7
8

Reserved (fixed as 0)

~

15

2:OUT reference

byte

Setting Data

4

Reference OUT: 0:OUT1, 1:OUT2

15:OUT16

5

Reserved (fixed as 0)

~

15

3:Threshold (level)

byte

Setting Data

4

Upper limit: 0.01μm unit. Sined 32-bit integer.

*Display range lower limit for the minimum display

unit Upper limit display range upper limit for

the minimum display unit

5
6
7
8

Lower limit: 0.01μm unit. Sined 32-bit integer.

*Display range lower limit for the minimum display

unit Lower limit dislay range upper limit for the

minimum display unit

9

10
11
12

Reserved (fixed as 0)

13
14
15

4:Threshold (Edge)

byte

Setting Data

4

Edge threshold: 0.01μm unit. Sined 32-bit integer.

*Display range lower limit for the minimum display
unit Edge threshold display range upper limit

for the minimum display unit

5
6
7
8

Edge direction: 0:Rising, 1:Falling

9

Reserved (fixed as 0)

10

Reserved (fixed as 0)

11

Reserved (fixed as 0)

12

Measurement count:

when batch off:Integer from 1 to 999,999

when batch on:Integer from 1 to Batch point

13
14
15

<Offset>

Type:10h~1Fh (10h:Program NO.0, 11h:Program NO.1,

, 1F:Program NO.15)

Category:06h, Item:0Dh
Target1:00h~0Fh (OUT1~16) Target2~4:00h

byte

Setting Data

0

Offset: 0.01μm unit. Sined 32-bit integer.

*Display range lower limit for the minimum display

unit Offset display range upper limit for the

minimum display unit

1
2
3