2.7 Additional Information

22

label orientation add function

Adds the orientation of bar code travel before the readout data.

Order of additional information

If you select to include all the additional information functions, they appear in the
following order:

You can change the delimiter as desired (one character), except the delimiter of
the scan count.

4 9 0 0 0 0 0 0

4

90

00

00

0

Forward orientation Reverse orientation

OK/NG

STABILITY

BL-180

r = F

:Forward

R

:Reverse

If an read error occurs, this information is not added.

Delimiter

r

:

Readout data

Code type

:

label

orientation

:

Readout data

:

Decode match

count

:

Scan count