3.3 Setup Software Operating Procedure

39

3. When you select Default[:] for Partition mark and Intermediate delimiter,

these parameters are set as below:

When you select Custom, the following appears:

Then, you can enter the desired value from the keyboard (using one character
for the partition mark and 5 characters or less for the intermediate delimiter).

4. Input the Read error using the keyboard.

You can change the code as desired (within 8 characters).

Normally, you should use the default setting (ERROR). You can chose not to
send the read error by selecting a null value for the read error.

5. Click the Return button or press [ENTER] to return to the communication

setting screen.

Header string, delimeter --> Page 48
Partition mark --> Page 21
Intermediate delimiter --> Page 13
Read error --> Page 48

3.3.12

Other setting

1. Place the mouse cursor at the item to be changed and click it, or move to the

target item by pressing [TAB]. Then, change the setting using [Space].

2. By setting Bepper for OK/NG output, the beeper beeps to indicate reading

stability during the normal reading operation.

3. To set OK/NG output duration, enter the appropriate numeric value from the

keyboard. The setting range is from 1 to 255 (10 ms to 2.55 s).

4. To set Compare with, enter the preset data to be registered from the key-

board.

Usually, specify the data within 32 characters. If you are using CODE128 and
the start character is CODE-C, you can set the data using up to 64 characters.

5. Click the Return button or press [ENTER] to return to the main setting

screen.

STABILITY LED --> Page 19
OK/NG output duration --> Page 10
Preset data --> Page 20