4.3 Command Communication

56

Setting Reading Mode/Data Addition Functions

Function

Command being sent

Respons

e

Description

Error

Code

Setting reading mode

Change

WP12n

OK

n= 0: Single label

1: Multi label 1
2: Multi label 2
3: Multi label 3

00, 02
05, 08
14

Confirm

RP12

12n

Setting data send timing

Change

WP13n

OK

N= 0: Sends data after reading

1: Sends after timing input turns off

00, 02
05, 07
14

Confirm

RP13

13n

Setting repeat-read time in
multi label reading mode 1 or
2

Change

WP41nnn

OK

nnn=001 to 225
(by 100 ms step)

00, 02
05, 09
14

Confirm

RP41

41nnn

Setting decoding match count Change

WP43nnn

OK

nnn=001 to 225

Confirm

RP43

43nnn

Setting decoding match count
in additional information

Change

WP10n

OK

n= 0: No addition

1: Add

00, 02
05, 07
14

Confirm

RP10

10n

Setting scans in additional
information

Change

WP11n

OK

n= 0: No addition

1: Add

Note:
Effective only when No. of decodings are added.

Confirm

RP11

11n

Setting label orientation in
additional information

Change

WP14n

OK

n= 0: No addition

1: Add

Confirm

RP14

14n

Setting code type in additional
information

Change

WP17n

OK

n= 0: No addition

1: Add

Confirm

RP17

17n