3 command communication – KEYENCE BL-180 User Manual

Page 62

Advertising
background image

4.3 Command Communication

54

Setting Bar Code Type and Number of Readable Digits for Codes 1 to 4

The following describes the parameter setting commands for Codes 1 to 4.

Be sure to send “Bar code type setting command” first before setting other param-
eters.

When “Bar code type setting command” is newly sent, all other parameters for the
specified code will return to the default settings.

In this case, set all other parameters again.

Setting change commands and setting confirmation commands are described on
the following pages.

Note

Function

command being sent

Respons

e

Description

Error

Code

Setting bar code type for
codes 1 to 4.

Change

CODEm=n

OK

m= 0 to 3:Codes 1 to 4
n= 0:CODE 39

1:ITF
2:Industrial2-of-5
3: Codabar
4: UPC/EAN
5: CODE128
6: COOP2-of-5
7: None

00, 01
03, 05
08, 14

Confirm

CODEm

mn

Setting Max. No. of readable
digits

Change

MAXm=nn

OK

m= 0 to 3: Codes 1 to 4
nn= 01 to 32
* For CODE39, Codabar: 03 to 32
* For ITF: 02 to 32
* For CODE128: 01 to 64
Note:
With EAN code, this command causes error.

00, 01
03, 04
05, 09
14

Confirm

MAXm

mnn

Setting Min. No. of readable
digits

Change

MINm=nn

OK

Confirm

MINm

mnn

Sending start/stop character.

Change

WCm00n

OK

m= 0 to 3: Codes 1 to 4
n= 0: Disable

1: Enable

00, 02
03, 04
05, 07
14

Confirm

RCm00

00n

Inspection of check digit
(Modulus 43)

Change

WCm01n

OK

m= 0 to 3: Codes 1 to 4
n= 0: Disable

1: Enable

Confirm

RCm01

01n

Function

Command being sent

Respons

e

Description

Error

Code

Sending check digit.

Change

WCm02n

OK

m= 0 to 3: Codes 1 to 4
n= 0: Disable

1: Enable

00, 02
03, 04
05, 07
14

Confirm

RCm02

02n

Inspection of check digit
(Modulus 10)

Change

WCm10n

OK

m= 0 to 3: Codes 1 to 4
n= 0: Disable

1: Enable

Confirm

WCm10

10n

Sending check digit.

Change

WCm11n

OK

m= 0 to 3: Codes 1 to 4
n= 0: Disable

1: Enable

Confirm

RCm11

11n

Sending start/stop character.

Change

WCm30n

OK

m= 0 to 3: Codes 1 to 4
n= 0: Disable

1: Enable

Confirm

RCm30

30n

Start/Stop character type

Change

WCm31n

OK

m= 0 to 3: Codes 1 to 4
n= 0: Lower case

1: Upper case

Confirm

RCm31

31n

Inspection of check digit

Change

WCm32n

OK

m= 0 to 3: Codes 1 to 4
n= 0: Disable

1: Enable

Confirm

RCm32

32n

Sending check digit

Change

WCm33n

OK

m= 0 to 3: Codes 1 to 4
n= 0: Disable

1: Enable

Confirm

RCm33

33n

CODE39

CODE39

CODE39

ITF

ITF

Codabar

Codabar

Codabar

Codabar

Advertising