3 code39 setup, 3 setup software operating procedure – KEYENCE BL-180 User Manual

Page 41

Advertising
background image

3.3 Setup Software Operating Procedure

33

4. When selecting Single for Read mode, the following appears on the screen:

When selecting Multi 1 or Multi 2, the following appears on the screen:

Set the time within the range from 1 to 255 (100 ms to 25.5 s).

When selecting Multi 3, none of the above information appears.

5. In the Additional information field, you can select one or more items. How-

ever, the scan count is given only when the decode count is selected.

Read mode --> Page 12
Data-send --> Page 11
Repeating-reading time --> Page 12
Decoding match count --> Page 10
Additional information --> Page 21

3.3.3

CODE39 setup

When setting CODE39 to any one of codes 1 to 4 and trying to set details, this
setting screen appears.

1. Place the mouse cursor at the item to be changed and click it, or move to the

target item by pressing

[TAB]

. Then, change the setting using

[Space]

.

2. Setting Max code length and Min code length allows the BL-180 to read bar

codes having the specified range of digits. If you want to read bar codes with
the specific code length, set the same value to both Max code length and
Min code length.

The allowable setting range is 3 to 32 digits including the start/stop character.

3. When you select Send start/stop character, * is added to the data when

being sent.

Note

Advertising