3 command communication, Setting communication strings – KEYENCE BL-180 User Manual

Page 67

Advertising
background image

4.3 Command Communication

59

Setting Communication strings

To set communication strings, send the following command.

Example 1: Set the communication data format to SOH 01 Bar Code Data ACR .

Example 2: Set the read error code to “BR”.

Example 3: Set no read error code.

Utility Setting (Buzzer, OK/NG output duration, Preset data for compare)

To register the preset data, send the following command.

Example: Register “ABC123” as preset data.

WP68ABC123CR

Function

command being sent

Response

Description

Error

Code

Setting header

Change

WP51hhh...

OK

hhh...= Header (Up to 5 characters)
* Specify characters in HEX (hexadecimal) code.
* To set no header, hhh...=FF.

00, 02
05, 06
10, 12
14

Confirm

RP51

51hhh...

Setting delimiter

Change

WP52hhh...

OK

hhh...= Delimiter (Up to 5 characters)
* Specify characters in HEX (hexadecimal) code.
* To set no delimiter, hhh...=FF.

Confirm

RP52

52hhh...

Setting partition mark when
additional information is used.

Change

WP50hh

OK

hh= Partition mark(1 character)
* Specify the mark in HEX (hexadecimal) code.
* To set no mark, hh=FF.

Confirm

RP50

50hh

Setting intermediate delimiter
when multi label reading
mode 2 or 3 is used.

Change

WP54hhh...

OK

hhh...=Intermediate delimiter (Up to 5 charac-
ters)
* Specify characters in HEX (hexadecimal) code.
* To set no intermediate delimiter, hhh...=FF.

Confirm

RP54

54hhh...

Setting read error code

Change

WP55hhh...

OK

hhh...= Read error code (Up to 8 characters)
* Specify characters in HEX (hexadecimal) code.
* To set no read error code, hhh...=FF.

Confirm

RP55

55hhh...

Note

WP51013031CR

0

0

SOH

WP52410DCR

CR

A

SOH=01h, 0=30h, 1=31h, A=41h, CR=0Dh

WP554252CR

R

B

B=42h, R=52h

WP55FFCR

Function

command being sent

Response

Description

Error

Code

Setting buzzer

Change

WP15n

OK

n= 0: on
1: on when OK output turns on.
2: on when NG output turns on.
3: off

00, 02
05, 07
14

Confirm

RP15

15n

Setting OK/NG output duration Change

WP40nnn

OK

nnn= 001 to 255
(by 10 ms step)

00, 02
05, 09
14

Confirm

RP40

40nnn

Registration of preset data for
compare

Change

WP68aaa...

OK

aaa...= Preset data (Up to 32 characters)
* For CODE128, see page 70.
* To delete the preset data, send WP68.

00, 02
05, 12
13, 14
17, 18

Confirm

RP68

68aaa...

Note

Advertising