Weighing input mode, Digital input mode – A&D Weighing GF-32K User Manual

Page 64

Advertising
background image

62

Using the "UN:mm" command, the unit mass can be recalled.

The unit mass recalled can be output using the "?UW" command.

The unit mass can be changed using the "UW:" command.

"mm" indicates a two-digit numerical value 01 to 50, which corresponds to p01 - p50 of the
GX-K series.

"mm" indicates a two-digit numerical value 01 to 20, which corresponds to p01 - p20 of the
GF-K series.


Weighing input mode

In the weighing input mode, the specified number of samples is placed on the pan to store
the unit mass. Re-storing the unit mass or performing Automatic Counting Accuracy
Improvement (ACAI) on the re-stored unit mass is possible. Follow the procedure described
in "6-2. Counting Mode (PCS)".

Use the following keys to store a unit mass in the weighing input mode.

RE-ZERO

key.. To set the display to zero.

10 - pcs

10 0 pcs

SAMPLE

key ... To change the number of samples to be stored.

10 0 pcs

25 0 pcs

PRINT

key....... Press, after a sample is placed, to store the unit mass. Go to step 3 of the

previous page.

CAL

key.......... To return to the unit mass confirmation mode. Go to step 3 of the

previous page.

MODE

key....... Press and hold to go to the digital input mode.


Digital input mode

To use this mode, the sample unit mass must be known

beforehand. In the digital input mode, the unit mass value is
entered digitally using the keys. The display in the digital input
mode is shown to the right.


Note ACAI can not be used on the unit mass stored

using the digital input mode.


Use the following keys to store a unit mass in digital input mode.

SAMPLE

key ... To select the digit to be changed.

RE-ZERO

key.. To change the value of the selected digit.

MODE

key ...... To change the decimal point position.

PRINT

key....... To store the unit mass. Go to step 3 of the previous page.

CAL

key.......... To return to the unit mass confirmation mode. Go to step 3 of the

previous page.

MODE

key....... Press and hold to go to the weighing input mode.


Note If the new unit mass is out of the setting range, "

error 2

" is displayed.

Refer to "20. Specifications" for the minimum unit mass.


Value

Digit

Decimal point

Store

Advertising
This manual is related to the following products: