Standard input & output interface, 1. rs-232c and external contact input – A&D Weighing GF-32K User Manual

Page 81

Advertising
background image

79

16. Standard Input & Output Interface

16-1. RS-232C And External Contact Input

D-Sub 25 pin numbers








D-Sub 25 pin assignments

Pin No. Signal name

Interface type

Direction

Description

1 FG

-

Frame ground

2 RXD

RS-232C

Input

Receive

data

3 TXD

RS-232C

Output

Transmit

data

4

RTS

RS-232C

Input

Ready to send

5

CTS

RS-232C

Output Clear to send

6

DSR

RS-232C

Output Data set ready

7 SG

RS-232C / external contact

input

- Signal

ground

18

PRINT

External contact input

Input

Same as the PRINT key

19

RE-ZERO

External contact input

Input

Same as the RE-ZERO key

Others

-

-

- No

connection


RS-232C

The balance is a DCE device. Connect the balance to a personal computer (DTE) using a
straight through cable.

Transmission system : EIA RS-232C
Transmission form

: Asynchronous, bi-directional, half duplex

Transmission rate

: 10 times/second or 5 times/second (same as data refresh rate)

Data format

: Baud rate : 600, 1200, 2400, 4800, 9600, 19200bps

Data bits : 7 or 8 bits

Parity

: Even, Odd (Data bits 7 bits)

None

(Data bits 8 bits)

Stop bit

: 1 bit

(When sending, 2 bits; receiving, 1 bit.

A personal computer will function with either setting.)

Code

:

ASCII



M2.6

ISO metric screw thread

Start bit

Data bits

Parity bit

Stop bit

-5V to -15V
+5V to +15V

RS-232C

Advertising