Section 3. Automatic

Temperature Control

АТС Functionary

The nozzle of the water valve directs the incoming
water over two thermostats mounted onto the upper

injector assembly. One of the thermostats controls the
cold water valve, and the other controls the hot water

valve.

When АТС cold wash is selected:
The cold water valve is opened forfuil cold fill. If the

incoming water temperature is below approximately
65°F, the hot water valve will open and warm the
incoming water. The hot water valve will continue to
cycle on and off maintaining optimum cold water
temperature until the tub is full. The target water

temperature for a cold wash is 70°F to 80°F.

When АТС warm wash is selected:
The hot water valve is opened for full hot fill. If the

Incoming water temperature is above approximately

100°F, the cold water valve will open and cool the

incoming water. The cold water valve will continue to
cycle on and off maintaining optimum warm water

temperature until the tub is full. The target water
temperature for a warm wash is 90°F to 100°F.

АТС is not active during rinse or hot wash.

Section 4. Water Valves

Water Valve Access

Water valve access is gained by lifting the top assem­

bly. The water valve is located just behind the Auto­
matic Temperature Control Assembly and mounted to

the back cabinet wall. To remove the water valve.

Disconnect water lines and remove one screw on the
leftside of the water valve mounting bracket. Slide
bracket to the left and remove.