SECTION 1. GENERAL INFORMATION

WASHER PRE-IIMSTALLATION

REQUIREMENTS

NOTE: Proper installation is the responsi­

bility of the purchaser.

Checkpoints for proper installation:

Properly grounded electrical outlet is
required. Use 15 amp fuse or compa­
rable circuit breaker for electrical
service.

Standpipe Drain System must be able to
accept IVa" O.D. drain hose. In cases
where an air tight connection is re­
quired, an anti-siphoning valve, part

number 12001586, should be placed in

the drain hose to prevent siphoning
from the washer or facility during

agitation. Standpipe height of 36" is

recommended.

NOTE: if drain standpipe is in excess of

5 feet above floor level, install pump
accessory kit, part number 12001587.

These units are not equipped with a

siphon break, and the drain hose must
be elevated to a minimum height of 36".
For installations with short standpipes,

the drain hose must be supported by

clipping the drain hose into the clip on

the back of the washer. Then a coupler

and additional hose length is added to

the existing drain hose.

Hot and Cold water faucets should be

within four (4) feet of the back of the
washer. This allows for quick access for

immediate shut off of the water.

Do not store or operate washer in tem­
peratures below freezing. This can cause
damage to the pump, hoses and other
components. (See page 1-5 for long term

storage.)

Water pressure of 20 -120 RS.I. is required
to fill the washer in the appropriate time
frame. Pressures of less than 20 RS.I. may

cause an extended or exceptionally long

fill time. Refer to the troubleshooting sec­
tion for more information regarding a so­

lution for slow fill situations.

Best performance is obtained with the

washer installed on a solid floor. Wood
floor constructions may need to be rein­
forced to minimize vibration from unbal­
anced load situations. Carpets and soft
tile surfaces are also contributing factors

in vibration and/or movement during the
spin cycle. Never install washer on plat­

form or weak support structure.

ELECTRICAL REQUIREMENTS

1. Provide an individual 120 volt, 60 HZ,

branch circuit with ground for the washer.

This circuit must be rated for 15 amperes

or more.

2. Protect the washer's electrical circuit with

a 15 ampere time delay fuse or circuit
breaker.

3. Install in accordance with National

Electrical Code and all local codes
and ordinances.

W

Water heater should be set to deliver a

minimum of 120° (49°C) hot water to

the washer.