MICROPROCESSOR TEMPERATURE CONTROL BOARD DIAGNOSTICS FOR MODEL
MAV8500

PIN

SOURCE

OUTPUT/

INPUT

WIRE

COLOR

MEASURE

TO PIN #

VOLTS

OHMS

CONDITIONS

1

Neutral

Input

WH

Line

120VAC

2

Not Used

3

WaterValve-Hot

Output

OR

1

120VAC

4

Cold Valve

Output

RD

1

120VAC

5

Indicator Light

Output

YL

1

120VAC

АТС Option Selected
Warm or Cold Wash

6

Line 1

Input

BU

1

120VAC

7

Fingertip Faucet

Input

PU

6

OVDC

12-24VDC

FF Button Not Pushed
FF Button Pushed

8

Timer Input (Chime)

Input

YL

6

OVDC

5VDC

Contact 9T or9B Closed
Contact 9T or 9B Opened

9

Chime Soft

Input

OR

6

12-24VDC

Soft Chime Selected

10

Chime Loud

Input

RD

6

12-24VDC

Loud Chime Selected

11

Temp Selector

Switch - Cold Wash

Input

BU

6

OVDC

Warm or Cold Wash

Selected

5VDC

Warm or Cold Wash

Deselected

12

Temp Control Enable

Input

BR

6

OVDC

12-24VDC

Option Deselected
Option Selected

13

Fingertip Faucet

Output

PU

6

24VDC

14

Chime Switch

Output

BU

6

24VDC

15

Temp Selector
Switch - Hot Wash

Input

OR

6

OVDC

Hot or Warm Wash
Selected

5VDC

Hot or Warm Wash
Deselected

16

Thermistor

Input

GY

17

10K-100K

OHMS

17

Thermistor

Input

GY

16

10K-100K

OHMS

18

Line 1

Input

PU

1

120VAC

Signature Circuit to tell

Board this is for a MAV8500

19

Open

Figure 8-7A

16009485-01

©1999 Maytag Appliances Sales Company

Section 8. Electrical Components & Testing

8-9