Timer line switch input, Water valve, Timer line switch input -8 – Maytag Atlantis User Manual

Page 80: Water valve -8

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

TIMER LINE SWITCH INPUT

The finger tip faucet is the only control board
function that will operate with the timer knob

pushed in. This is monitored through cam 0
of the timer. Line voltage is routed through

the timer and when the timer knob is pulled

out, cam 0 closes and routes line voltage to a

1/4" spade terminal labeled Timer Sense on

the temperature control board.

TEMPERATURE CONTROL BOARD TEST

PROCEDURE(MAV8000,

MAV8057

&

MAV8500)

This procedure exercises all circuit board in­

puts and outputs such as thermistor, tempera­
ture signal light and audible signal. The only
exception is the connection to the "WHEN TO
CHIME" cam of the timer.

1. Turn Temperature Control OFF. Check fill

in both wash and rinse at each of the vari­
ous temperature settings for proper opera­
tion. This checks outputs of the tempera­
ture option switch and the water valve so­

lenoids. If all are OK, proceed to step 2.

Note: if a mistake is made in executing

the following sequence, it may be repeated
at any time by returning to step 2.

2.

Confirm that the Temperature Control

Switch is OFF, End-of-Cycle Signal Switch
is OFF. Note: The timer can be set to any

position.

(Steps 3 through 9 must be accomplished

within 20 seconds from start to finish.)

3. Press and release the FINGER FAUCET

switch. (Water will flow for 7 seconds un­

til step 9 is complete, presuming the pres­

sure switch is not satisfied.)

4. Switch TEMPERATURE CONTROL ON.

5. Switch SIGNAL LOUD SWITCH ON.

6. Switch TEMPERATURE CONTROL OFF.

7. Switch SIGNAL LOUD SWITCH OFF.

8. Switch TEMPERATURE CONTROL ON.

9. Switch SIGNAL LOUD SWITCH ON.

10. End-of-Cycle Signal will sound and the

Temperature Control Indicator Lamp will

light and remain on for 20 seconds.
(Should the Indicator light blink at a fast
rate of 0.2 seconds on, 0.2 seconds off, this
is an indication that the water valve ther­
mistor is either open or shorted.)

WATER VALVE

The water valve is secured to a bracket in­

side the left rear cabinet area by two (2)
mounting screws. The bracket may be re­
moved for service.

The water valve has two solenoids, one on

the "HOT' water side and another on the

"COLD" water side. These solenoids are en­
ergized through the timer, temperature con­
trol board (MAV6000, MAV6057, MAV7000,

MAV7057,

MAV8000,

MAV8057 and

MAV8500) and water temperature selector
switch and will allow COLD, HOT or WARM

(a mixture of HOT and COLD) water to enter

the tub as directed.

Testing Water Valve

The water valve can be accessed by raising
the top. The valve can be tested using an

ohmmeter and performing the following:

1. Disconnect power to the unit.

2. Remove all wiring from the solenoid(s)

being tested.

3. Place the test leads across the terminals

of the solenoid being tested. The meter
should indicate continuity.

--

16009485-01

Section 8. Electrical Components & Testing

©1999 Maytag Appliances Sales Company

8-10