Maytag Atlantis User Manual

Page 16

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Setting

Gallons

*Depth

Inches

*Basket

Perforations

Mini

10.5

6"

3 1/2“

Medium

14.1

8 1/2“

5“

High

19.5

11"

7“

Super

23.3

13 1/2“

9 1/4"

^Allowable variations are plus or minus 1/2 inch.

AGITATOR SPEED

Regular Cycle

88 Oscillations per minute

155 Degree Arc

Slow (Delicate) Cycle

57 Oscillations per minute

155 Degree Arc

SPIN SPEED

Regular Cycle

620 R.RM.

Slow (Fine Wash) Cycle

410 R.RM.

TABLE 1-1. AMPERAGE CHART

CYCLE

WATER

LEVEL

♦AMPS

Agitate-Regular

Full Tub

10.4

Agitate-Slow

Full Tub

7.6

Agitate-Regular

DryTub

7.5

Spin-Regular

DryTub

10.2

Spin-Slow

DryTub

7.6

Pump Out-Regular

Full Tub

10.8

Pump Out-Slow

Full Tub

8.0

TABLE 1-2. RESISTANCE CHART

COMPONENTS

♦RESISTANCE

(OHMS)

Timer Motor

2360

Mixing Valve

500-1000

Cold Solenoid

853

/Vof Solenoid

867

Drive Motor

High Speed

1.3

Low Speed

2.3

Start

3.1

* These values can vary slightly.

TABLE 1-3. WATTAGE CHART

CYCLE

♦WATTAGE

RANGE

Agitate-Regular

Full Tub

610-640/670 (MAX.)

Agitate-Slow

Full Tub

370-400/420 (MAX.)

Agitate-Regular

DryTub

460^70/480 (MAX.)

Agitate-Slow

DryTub

350-360/370 (MAX.)

Pump Out-Regular

760

Pump Out-Slow

510

Spin-Regular

Full Tub

460

Spin-Slow
Full Tub

340

* These will vary with washer load and line voltage.

16009485-01

©1999 Maytag Appliances Sales Company

Section 1. General Information

1-8

Advertising