Water inlet flume, Air bell, Water inlet flume -2 air bell -2 – Maytag Atlantis User Manual

Page 42

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

WATER INLET FLUME

HOSES

The molded plastic water inlet flume consists

of an upper and lower section that has been
snap-locked together.

The flume is located on the rear underside of
the washer top assembly. The flume fits flush
with the top opening and is secured to the top

by one mounting screw, accessed through the
control console. An inlet hose from the wa­

ter mixing valve connects to the flume nozzle.

AIR BELL

Water Supply Inlet Hoses

Two (2) water inlet hoses attach from hot and

cold water supply lines to their respective
nozzles on the water mixing valve. They are
secured at both ends with threaded couplings.

Flume Inlet Hose

The flume inlet hose attaches the water mix­

ing valve to the water inlet flume. It is secured
at both ends with spring type hose clamps.

Pressure Switch Hose

The pressure switch hose is made of soft plas­
tic tubing and fits snugly over the water level

switch nipple at one end, and the air bell nipple
at the other. A clamp on the inner cabinet rear
positions the hose, and a pad prevents the
hose from contacting the back of the cabinet
during operation. The hose is installed with
its ends seated against the switch and air bell
bodies, and is secured at the tub ends with a
spring type hose clamp.

Tub to Pump Hose

A polypropylene air bell and nipple assembly

have been thermally welded to the lower, outer

tub, rear. One end of the pressure switch hose

connects to the air bell nipple and the other
end is attached to the water level switch.

As the water level rises in the tub, it com­

presses the air in the air bell and the attached
hose. The compressed air inside the hose will
activate the pneumatically operated water
level switch when the selected water level has
been reached. When the air pressure is low­
ered during the drain cycle, the switch will
reset.

N OTE ; When reinstalling the pressure switch

hose, make sure the system is free of air leaks
and water in the hose or an overflow condi­
tion will occur.

The tub to pump hose attaches from the drain

outlet on the tub to the pump inlet. It is se­
cured at each end with a spring-type hose
clamp.

Drain Hose

The drain hose attaches the pump outlet to
the drain standpipe. It is secured to the pump
with a spring-type hose clamp.

16009485-01

Section 5. Water Related Components

5-2

©1999 Maytag Appliances Sales Company

Advertising