Maytag Atlantis User Manual

Page 90

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Figure 8-19

Figure 8-20

Unfortunately, the resistive carbon fuse link can­
not be easily detected with a regular ohm
meter.

An easier and more accurate method would

be to measure the resistance between LINE and
MACHINE terminals (Figure 8-20).

A properly functioning machine should show
a CLOSED circuit between LINE and MACHINE,

regardless of lid position.

Terminals

Continuity

Check With

Lid Open

Continuity

Check with

Lid Closed

LI (Line to

SW (Machine

Continuity

Continuity

LI (Line to M

(Motor

No

Continuity

Continuity

16009485-01

Section 8. Electrical Components & Testing

©1999 Maytag Appliances Sales Company

8-20

Advertising