LID SWITCH

Models MAV4057/4500/5000/5057

8000/8057

WATER SELECTOR SWITCH

POSITION

CIRCUIT

H-C

BK*-PK*

w-w

BK*-PU*, OR**-BU**,

BK*-PK*

w-c

BK*-PK*, BK*-PU*

c-c

BK*-PU*

* 1/4" Terminals -

» 3/16“ Terminals

The lid switch assembly is designed to inter­

rupt voltage to the wash motor in the event

the lid is raised. The switch is a single pole,
throw type with normally open contacts.

The normally OPEN set of contacts in the

switch are held CLOSED by a fusible link
(Figure 8-18).

Models MAV6000/6057/7000/7057

WATER SELECTOR SWITCH

POSITION

CIRCUIT

H-C

BK*-PK*, BU**-OR**

w-w

BK*-PU*, BK*-OR**

BK*-PK*

w-c

BK*-PK*, BK*-PU*,

BU**-OR**

c-c

BK*-PU*, BU**-OR**

* 1/4" Terminals

** 3/16" Terminals

Models MAV8500

WATER SELECTOR SWITCH

POSITION

CIRCUIT

H-C

BK*-RD*

w-w

BK*-RD*, BU**-RD**
BU**-OR**

w-c

BK*-RD*, BU'^*-RD**

c-c

BU**-RD**

* 1/4" Terminal

** 3/16" Terminal

Should a switch malfunction, current is di­
rected through the fuse link causing it to break­
down. Once the fuse link opens, the formed
contact spring arm opens and the power to
the machine is permanently disabled. Note,
the schematic representation in (Figure 8-19).