[Example 2] External digital trigger with post trigger

DO data Count: 8 samples

Trigger Event: DO-Start (rising edge)

Re-Trigger Count: 3

Figure 3-23: DO Post Trigger

[Example 3] External digital trigger with post trigger and re-trigger

DI data Count: 4 samples per trigger

Trigger Event: DI-Start (rising edge)

Re-Trigger Count: 3

Figure 3-24: DI Post Trigger with Re-trigger

DO Sampled Clock

DO-Start

(rising)

DO Data

Write 8 data

to external device

Wait for

DO-Start

t

w

t

w

= Minimum required pulse width time

Operation End

DI Sampled Clock

DI-Start

(rising)

DI Data

Read 4 data

into DI FIFO

Wait for

Trigger

t

w

t

w

= Minimum required pulse width time

Operation End

Wait for

Trigger

Read 4 data

into DI FIFO

Wait for

Trigger

Read 4 data

into DI FIFO