Function Block and Operation Theory

[Example 4] External digital trigger with post trigger and re-trig-
ger

DO data Count: 4 samples per trigger

Trigger Event: DO-Start (rising edge)

Re-Trigger Count: 3

Figure 3-25: DO Post Trigger with Re-Trigger

[Example 5] External digital trigger with gated trigger

DI data Count: 12 samples

Trigger Event: DI-Pause (logic high)

Figure 3-26: DI Gated Trigger

DO Sampled Clock

DO-Start

(rising)

DO Data

Write 4 data

to external

device

Wait for

Trigger

t

w

t

w

= Minimum required pulse width time

Operation End

Wait for

Trigger

Wait for

Trigger

Write 4 data

to external

device

Write 4 data

to external

device

DI Sampled Clock

DI-Pause

(logic high)

DI Data

Read 4 data

into DI FIFO

Operation End

Read 8 data

into DI FIFO

Operation Start

DI Acquisition

Paused