6 appendix, 1 hsl-4xmo commmand executuion time, Hsl-4xmo commmand executuion time – ADLINK HSL-4XMO User Manual

Page 113: 6appendix

Advertising
background image

Appendix

103

6

Appendix

6.1 HSL-4XMO Commmand Executuion Time

The testing is conducted at 6MHz baud rate and full-deplux mode.
We list the execution time depending on the command delivering
counts.

The time is measured with one, four, and eight modules respec-
tively. The time unit is mini-second. We have the classification as
follows.

The time is averaged with one thousand testing. The result is as
follows.

Command Type

Contents

Note

1

Send simple command

None

2

Send U16 command

None

3

Send U32 command

None

4

Get U16 command

None

5

Get U32 command

None

6

One-axis motion

6 Delivering Times

7

Two-axis motion

7 Delivering Times

8

Short-term motion

2 Delivering Times

Table 6-1: Commmand Executuion Classifications

Command

Type

Time (ms)

Example

One module

(ID: 1, 3, 5, 7)

Four modules

(ID: 1-16)

Eight modules

(ID: 1-32)

1

0.413

0.500

1.000

HSL_M_set_pls_outmode

2

0.429

0.501

1.000

HSL_M_set_home_config

3

0.453

0.501

1.000

HSL_M_set_position

4

0.497

0.505

1.000

HSL_M_get_io_status

5

0.500

0.509

1.000

HSL_M_get_position

6

2.588

3.023

6.000

HSL_M_start_tr_move

7

3.026

3.500

7.000

HSL_M_start_tr_move_xy

8

0.850

1.012

2.000

HSL_M_move_t_distance

Table 6-2: HSL-4XMO Commmand Executuion Times

Advertising