Block to another in the window shown in, Figure 54 – CIRCUTOR DISPENSER Series User Manual
Page 51
Advertising

Figure 54:Create a new tariff (Energy blocks)
Table 17:Create a new tariff (Energy blocks)
Definition of conditions
Parameter
Description
Range of values
Default
values
Period
Energy block operating period. When the period is
about to end, the energy meter resets the value of
consumed energy to start consuming from Block
1.
Day, Week, Month
Day
Block 1, 2 and 3
Price factor
Energy price factor
Block 1 and 2 :
0���5
Block 3:
0���65
0
Block 1 and 2
Energy
Consumption of energy after which the system
skips to a different block.
0���65
kWh
0
6�- Advanced
The end of the contract validity period is configured in the Advanced window,
Figure 55:Create a new tariff (Advanced Mode)
51
Instruction Manual
Dispenser Universal System
Advertising