Axel AX3000 65 User's Manual - firmware 0632 User Manual

Page 151

Advertising
background image

Installing under OS/400


AX3000 - User's Manual

137

The supported resources are:

- Screen sessions: SESS1, SESS2...
- Auxiliary ports: AUX1, AUX2, PARALLEL, NETx and USBx.

Use the following command to reset a resource:

===> RUNRMTCMD CMD('AX_SINIT password RESS') RMTLOCNAME('192.1.1.241' *IP)

Where:

- AX_REBOOT : Command for AX3000 resource reset,
- password

: Specify the set-up password if set,

- 192.1.1.241 : AX3000 IP address.
- RESS

: Resource name (ex: SESS1).

c) Editing the AX3000 Settings

The whole AX3000 set-up can be obtained by invoking the following command:

===> RUNRMTCMD CMD(SETUP_GET) RMTLOCNAME('192.168.1.241' *IP)

or a partial set-up can also be obtained (only used set-up parameters are sent):

===> RUNRMTCMD CMD(SETUP_GET_LITE) RMTLOCNAME('192.168.1.241' *IP)

Where:

- SETUP_GET

: Command for getting the whole set-up,

- SETUP_GET_LITE : Command for getting the partial set-up,
- 192.168.1.241

: AX3000 IP address.

For more information about these commands, refer to Chapter 10.

d) Setting-Up the AX3000

No OS/400 command allows the contents of a set-up file to be sent over the
network. The following example describes the use of rsh Windows command:

c:\> rsh 192.168.1.241 setup_send password < /tmp/axel

Where:

- 192.168.1.241 : AX3000 IP address,
- setup_send

: Command for set-up the AX3000,

- password

: Specify the set-up password if set.

Advertising