Led and beeper indications – Datalogic Scanning POWERSCAN 7000 User Manual

Page 11

Advertising
background image

LED and Beeper Indications

Product Reference Guide

1-3

LED and Beeper Indications

The imager is equipped with a beeper (speaker) and two indicator LEDs;
one green and one yellow. These indicators “beep” or flash when certain
actions take place:

NOTE

Some LED and Beeper indications are user-con-
figurable for volume, pitch, quantity, duration,
enable/disable, etc. Those listed in the following
table assume the feature is enabled. See the
Product Reference Guide (PRG) for detailed pro-
gramming information.

Condition

Green LED

Beeper

Powering On
UKBW/RS-232 Models
(using UKBW interface)

2 normal flashes and 2 fast flashes

(+ 1 normal flash with Smart cable)

One Beep

Powering On
UKBW/RS-232 Models
(using RS-232 interface)

2 normal flashes and 1 long flash

One Beep

Powering On
All Other Models

Bright Green Flash

One Beep

Good Read

1 - 9 Bright Green Flash(es)

a

a. Good Read indications are synchronous. That is, if Good Read beeps

are set via programming to five (for example), the Good Read LED will
also flash five times.

1 - 9 Beep(s)

a

Error Indication

Green Flash

Special Beep

Condition

Yellow LED

Beeper

Ready to Operate

Yellow LED on steady until trigger is pulled

None