Symbologies

6-6

PowerScan

®

7000 2D

Code 39 Check Character

No Check Character

indicates that the imager reads and transmits bar code

data with or without a check character.

When Check Character is set to

Validate, but Don’t Transmit

, the unit only

reads Code 39 bar codes printed with a check character, but will not
transmit the check character with the scanned data.

When Check Character is set to

Validate and Transmit

, the imager only

reads Code 39 bar codes printed with a check character, and will trans-
mit this character at the end of the scanned data. Default = No Check
Character.

Code 39 Message Length

Scan the bar codes below to change the message length. Refer to

Mes-

sage Length Description on page 6-2

for additional information. Mini-

mum and Maximum lengths = 0-48. Minimum Default = 0, Maximum
Default = 48.

Validate, but Don’t Transmit

* No Check Character

Validate and Transmit

Minimum Message Length

Maximum Message Length