OCR Programming

8-8

PowerScan

®

7000 2D

To create this template, you would enable the OCR-A font. Scan the

Enter OCR Template

symbol (

page 8-16

). Scan the

d

from the

OCR Pro-

gramming Chart on page B-4

in the back of this manual three times, then

scan

2041424320

from the

Programming Chart on page B-5

(the hex char-

acters for “space,” “A,” “B,” “C,” “space”). Scan the

d

three more times,

then scan

Save OCR Template

(

page 8-17

). This would let you read any

string of three digits, space, “ABC,” space, then any string of three digits.
For example:

551 ABC 983

4. Exit OCR Template Editor

Scan

Save OCR Template

to save your entries.

Discard OCR Tem-

plate

exits without saving any OCR Template changes.

Stringing Together Multiple Formats
(Creating “Or” Statements)

You may want to program the imager to accept many OCR formats. To
do this, you would string together each format with a “t.” This tells the
imager to read optical characters that match any one of the formats in
the template.

Example:

You need to read any combination of eight digits, or a combination of four

digits, two uppercase letters, and two digits. The template would be:

ddddddddtddddlldd

To create this template, you would enable the OCR-A font. Scan the

Enter OCR Template

symbol (

page 8-16

). Scan the

d

from the

OCR Pro-

gramming Chart on page B-4

eight times, then scan the

t

to create the “or”

statement. Then you would scan the characters for the second template.
Scan

d

four times, scan

l

two times, then scan

d

two more times. Scan

Save OCR Template

(

page 8-17

). This would let you read either type of

format, for example:

99028650

or

9902XZ50

NOTE

If using PowerView to program, use the space
bar to designate a space and not the hex value
of 20.