Datalogic Scanning POWERSCAN 7000 User Manual

Page 58

Advertising
background image

Data Editing

4-4

PowerScan

®

7000 2D

Example: Add a Suffix to a specific symbology

To send a CR (carriage return)Suffix for UPC only:

Step 1.

Scan Add Suffix.

Step 2.

Determine the 2 digit hex value from the Symbology Chart (included
in

ASCII Conversion Chart (Code Page 1252) on page A-4

) for UPC.

Step 3.

Scan 6, 3 from the

Programming Chart on page B-5

of this manual.

Step 4.

Determine the hex value from the

ASCII Conversion Chart (Code

Page 1252) on page A-4

, for the CR (carriage return).

Step 5.

Scan 0, D from the

Programming Chart on page B-5

of this manual.

Step 6.

Scan Save, or scan Discard to exit without saving.

To Clear One or All Prefixes or Suffixes:

You can clear a single prefix or suffix, or clear all prefixes/suffixes for a
symbology. When you Clear One Prefix (Suffix), the specific character
you select is deleted from the symbology you want. When you Clear All
Prefixes (Suffixes), all the prefixes or suffixes for a symbology are deleted.

Step 1.

Scan the Clear One Prefix or Clear One Suffix symbol.

Step 2.

Determine the 2 digit Hex value from the Symbology Chart (included
in

ASCII Conversion Chart (Code Page 1252) on page A-4

) for the

symbology from which you want to clear the prefix or suffix.

Step 3.

Scan the 2 digit hex value from the

Programming Chart on page B-5

of this manual or scan 9, 9 for all symbologies.

Your change is automatically saved.

To Add a Carriage Return Suffix to all Sym-
bologies

Scan the following bar code if you wish to add a carriage return suffix to
all symbologies at once. This action first clears all current suffixes, then
programs a carriage return suffix for all symbologies.

Add CR Suffix

All Symbologies